Multimode- vs. singlemode-fiber standards

Dec. 1, 1997

Multimode- vs. singlemode-fiber standards

By WILLIAM B. GARDNER

The first optical-fiber standards, written in the late 1970s, dealt exclusively with multimode fibers. When singlemode fibers entered the marketplace in the 1980s, there was a natural desire to carry multimode concepts, definitions, and test methods over into the singlemode standards. Sometimes this worked (as with cladding diameter and proof testing, for example), but many times it didn`t. Here are three examples of multimode concepts that do not apply to singlemode fiber:

Numerical aperture (NA)--Multimode standards such as the International Telecommunication Union`s (itu`s) Recommendation G.651 on 50/125-micron graded-index fiber define a maximum refractive index of the core and a cladding refractive index. These two parameters are then used to calculate the theoretical NA of the fiber. The actual NA is determined by measuring the divergence angle of the cone of light leaving the fiber (see, for example, the Telecommunications Industry Association [tia] test method fotp-177). The theoretical and actual NA are nearly equal and provide a useful measure of how much light the fiber can capture from an incoherent source.

The concept of NA is based on geometrical optics, or "ray-tracing," which works well in multimode fibers but not in singlemode fibers. All of the itu`s singlemode recommendations (G.652, G.653, G.654, and G.655) contain the words "the refractive index profile generally does not need to be known." Although singlemode profile measurements are difficult because of the small core, they can be done. But even if the maximum refractive index of the core were measured, inserting that value into the formula for theoretical NA would not give the correct divergence angle for the singlemode fiber`s radiation cone.

Because NA is strictly a geometrical optics concept, the term isn`t even defined in singlemode fiber standards.

Core diameter--The automated gray-scale analysis, which is so useful in making accurate multimode core diameter measurements (see tia`s fotp-176), is of little value in singlemode-fiber measurement, because the core size is so close to the resolution limit of optical measurements. This fundamental resolution problem contributed to the replacement of core diameter with mode field diameter in singlemode fiber standards. Core diameter and NA are important for predicting splice loss in multimode fibers; mode field diameter alone serves this purpose in singlemode fiber.

Prescribed launch conditions--Because attenuation and bandwidth values in multimode fibers depend on which modes are excited, the test methods prescribe how the launch conditions are to be controlled. For example, tia`s fotp-50 offers two options for attenuation measurements: mode filters and beam optics. The mode filter is created by wrapping five turns of the fiber around a mandrel whose diameter is 20 to 25 mm (the exact value depends upon the fiber type).

There is no such requirement for selecting the modes to be launched when measuring singlemode fiber attenuation, since the fiber propagates only one mode. Nevertheless, the use of short (a few meters) fiber lengths in the measurement could allow the presence of a higher-order mode to influence the measurement. tia`s fotp-77 provides guidance on the selection of a mode filter (yes, a mandrel wrap) to ensure that this doesn`t happen. But the considerations are not the same as those in fotp-50.

Equivalences between multimode and singlemode fiber concepts are not only imperfect, but sometimes even nonexistent. q

Sponsored Recommendations

Coherent Routing and Optical Transport – Getting Under the Covers

April 11, 2024
Join us as we delve into the symbiotic relationship between IPoDWDM and cutting-edge optical transport innovations, revolutionizing the landscape of data transmission.

Scaling Moore’s Law and The Role of Integrated Photonics

April 8, 2024
Intel presents its perspective on how photonic integration can enable similar performance scaling as Moore’s Law for package I/O with higher data throughput and lower energy consumption...

From 100G to 1.6T: Navigating Timing in the New Era of High-Speed Optical Networks

Feb. 19, 2024
Discover the dynamic landscape of hyperscale data centers as they embrace accelerated AI/ML growth, propelling a transition from 100G to 400G and even 800G optical connectivity...

Advancing Data Center Interconnect

July 31, 2023
Large and hyperscale data center operators are seeing utility in Data Center Interconnect (DCI) to expand their layer two or local area networks across data centers. But the methods...